Products

DX-210B Fluxmeter

With the design of low-drift electronic integrating circuit, DX-210B High precision low drift fluxmeter is mostly characterized by the rapid testing induction response, high test accuracy and no loss of testing data. Test range: 2mwb, 20mwb, 200mwb, 2000mwb four files (can be changed as needed); Corresponding input impedance: 1k ohm, 10k ohm, 100k ohm, 1000k ohm; Drift: 1uWb / min.

contact now

DX-210B Fluxmeter


With the design of low-drift electronic integrating circuit, DX-210B low drift fluxmeter is mostly characterized by the rapid testing induction response, high test accuracy and no loss of testing data. The user can measure samples with pulling method, and the test date can nearly be independent from the pulling speed. The repeatability of tested magnetic flux date is good. DX-210B low drift fluxmeter is a good integrator which can simulate the circuit design and with wide applications.

 

Features
● Directly read magnetic flux data;
● Judge the direction of integration by “+” or “-”;
● Suitable for matching with different integration coils and fixtures;
● Adjust stably, low drift, less than 1uWb/min;
● High input impedance, the coil has small effect on the test.
● Inspection of conventional DC magnetic field;

 

Technical index
● Test range: ± 3.0000mWb \ ± 30.000mWb \ ± 300.00mWb \ ± 3000.0mWb four levels (can be changed as required);
● Corresponding input impedance: 1k ohm, 10k ohm, 100k ohm, 1000k ohm;
● Power supply: AC 50Hz, 220V0.5A;
● High precision, full-scale accuracy reaches ± 0.1%, resolution error range is ± 1/30000;
● Drift degree: very low integral drift, after the warm-up reaches a stable state, the minimum drift amount within 24 hours is less than 1uWb;
● Minimum resolution: 0.1uWb (corresponding to 3mwb range);
● Volume: 285mm × 300mm × 100mm, weight: 3kg; (width * depth * height);
● Operating environment: -45 ℃ -38 ℃; humidity:<85%; environmental sea wave: <3500 meters.

 

Function introduction:

 

1. Test range: ± 3.0000mWb \ ± 30.000mWb \ ± 300.00mWb \ ± 3000.0mWb. Press the F1 key on the panel keyboard to switch the range, from low gear to high gear. Press the key cycle to switch. Second gear (± 30.000mWb), the current test range will be displayed in the upper left corner of the screen.

2. Clear the reading: Press Zero to clear the integrator.

3. Drift adjustment: Press the Adj key, and the software enters the automatic drift adjustment state. At the same time, Adj ... will be displayed at the bottom left of the screen, indicating that drift adjustment is in progress. When adjusting the drift, you should keep the static state without the magnetic flux signal input, and avoid other interference signals. At the same time, you cannot press the Zero key. The drift adjustment time varies from a few seconds to 30 seconds. After Adj is over, if the displayed value is not, you can press Zero to clear it.

4. Signal input: The magnetic flux inductive coil can be connected to the INPUT on the rear panel. The INPUT includes two terminals, which are respectively connected to the two ends of the measuring coil; in addition, the Probe port can also be connected to the measuring coil of the corresponding interface.

5. Calibration of measurement results: Press the Menu key to enter the CAL menu. There are 4 coefficients in this menu. These coefficients can be modified by pressing the number keys and the arrow keys. These coefficients are the calibration parameters of the magnetic flux, which have a linear relationship with the measurement results. They have been calibrated before leaving the factory. Under normal circumstances, users are not recommended to modify them by themselves.

6. Analog output: The interface is the BNC labeled OUTPU on the rear panel, which corresponds to a full-scale voltage of 3V.

7. The communication interface: RS232. At present, no user protocol is available for this communication.

8. Note: After the range is switched, the drift of the flux meter will change greatly, and the drift adjustment needs to be performed again. After the drift adjustment is completed, the flux meter does not necessarily reach a very stable state. After waiting for several tens of seconds, the flux meter will reach stability.


inquiry now

We will give you a quotation within 24 hours.



Main Products
  • DX-2012HC Soft Magnetic Material Coercivity Measuring Device DX-2012HC Soft Magnetic Material Coercivity Measuring Device

    DX 2012HC soft magnetic material coercivity measuring device is mainly used for rapid measurement of soft materials including: pure iron and carbon steel, soft ferrite, magnetic powder and other regular and irregular open circuit samples, and the test method is reliable.

  • DX-100 Hall Effect Measurement System DX-100 Hall Effect Measurement System

    DX 100 Hall effect test system can be divided into normal temperature, high temperature, low temperature, high and low temperature Hall effect test system; It is used to measure the carrier concentration, mobility, resistivity, Hall coefficient, etc. of semiconductor materials; It is an essential tool for studying the electrical properties of semiconductor materials.

  • DX-9000 Series Vibration Sample Magnetometer DX-9000 Series Vibration Sample Magnetometer

    DX-9000 series vibrating sample magnetometer is a kind of magnetometer developed by Xiamen Dexing Magnet Tech. Co., Ltd. The main research and development of the magnetic material measurement system is a new generation of products based on the electromagnet platform.

  • DX-2100AM Magnetization Angle Measurement System DX-2100AM Magnetization Angle Measurement System

    The DX 2100AM magnetization angle measurement system is connected to the independent three component fluxmeter by a three dimensional Helmholtz coil to form a hardware test part;Through a microcomputer conversion of the test data of three components, a complete magnetization angle measurement system is formed.